Turn the thermometer pointer screw located inside the front cover to change the setting. AIRXCEL Suburban Gas Furnaces This book contains instructions covering the operation and maintenance of your furnace. Thermostat and Manual Reset. Replacement Parts List. and safe operation, as well as adequate clearances for accessibility. Should you require further information, contact your dealer or nearest Suburban Service Center Direct vent gas water heater for installation in recreational vehicles and mobile housing (13 pages), Direct vent gas water heater direct spark ignition (dsi) (24 pages), Direct vent gas water heater direct spark ignition (dsi) (13 pages), Direct vent gas water heater direct spark ignition dsi (7 pages), Direct vent gas water heater direct spark ignition (dsi) (6 pages), Direct vent gas water heater direct spark ignition (dsi) for installation in recreational vehicles and mobile housing (7 pages), Manual will be automatically added to "My Manuals". LISTED ON THE WARRANTY, OR RATING PLATE WHICH CAME WITH YOUR WATER HEATER. At this manual to suburban rv furnace thermostats are extensively tested twice during the most trusted names in the show where there is at no holes where the thermostat. INSTALLER: AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO W ATER HEATER. Should you require Installation, Operation and Maintenance Manuals, please click here to submit your request. Manual will be automatically added to "My Manuals", Furnace Suburban NT-16SEQ Installation Manual, Furnace Suburban Airxcel Suburban NT-16SEQ User's Information Manual, Furnace Suburban NT-24SP User's Information Manual, Furnace Suburban NT-24SP Installation Instructions Manual, Furnace Suburban NT-40 User's Information Manual, Furnace Suburban DYNATRAIL NT-40 Installation Instructions Manual, Furnace Suburban NT.12SE User's Information Manual, Furnace Suburban NT-12SE User's Information Manual, Furnace Suburban NT-16SE User's Information Manual, Furnace Suburban NT-16SQ User's Information Manual, Furnace Suburban NT-12S Installation Manual, Furnace Suburban SF-20Q Installation Instructions Manual. for installation in recreational vehicles and mobile housing . Parts Illustration and Replacement Parts List. Operating Instructions. The thermostat wires were stripped, twisted together, and connected to one of the blue blue/white wires, and the other blue was not connected to anything. IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT. Our furnace has always worked, so I'm wondering if I'm missing something. 4. 5. National Fuel Code ANSI Z223.1/NFPA 54. QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. DRAIN HEATER IF SUBJECT TO FREEZING TEMPERATURES. Mount the thermostat base to the sub - base using the three captive screws on the thermostat base. Cold air passing over, the furnace combustion chamber during the operation of the cooling unit can result, in the formation of condensation inside the furnace combustion chamber. b. of local building codes, refer to the latest edition of: 1. OW NER: RETAIN THESE INSTRUCTIONS AND W ARRANTY FOR FUTURE REFERENCE. in. LIQUIDS OR VAPORS ARE LIKELY TO BE PRESENT. AN ODORANT IS ADDED TO THE GAS USED BY THIS W ATER HEATER. Suburban Thermostat 140 Degree Water Heater Switch - 120V : Alternative Views: Price: $ 24.64. Heating: 0.15 to 1.2 Amps. 1. Preventive Maintenance. SUBURBAN MANUFACTURING COMPANY 676 Broadway Street Dayton, Tennessee 37321 423-775-2131 Fax: 423-775-7015 www.rvcomfort.com info1@suburbanmfg.com fTABLE OF CONTENTS Page Appliances and Equipment in Recreational Vehicles. RV Products suggests the thermostat wiring be a minimum of 18 gauge. 1. The Suburban Thermostat is a single stage heat only RV thermostat that works perfectly with your furnace. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. In order for these furnaces to operate in conformity with, generally accepted safety regulations, the installation instructions outlined in this book must be followed. Furnaces. SUBURBAN FURNACE NT-20SEQ EXPLODED PARTS VIEW LINKS. Anticipator Rating: Heating - Adjustable from 0.15 to 1.2 Amps. Select a location for installation out of the way of wires, pipes, etc. DO NOT TOUCH ANY ELECTRIC SWITCH: DO NOT USE ANY PHONE IN YOUR. Connection: Screw termination. Refer to the installation instructions and/or owners manual provided with this. LISTED ON THE W ARRANTY, OR RATING PLATE W HICH CAME W ITH YOUR W ATER HEATER. are designed and tested under the same standards as the 12-volt models. 11. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A. All do-it-yourself projects entail some risk. Item# 7 Intake Tube, 5 Inch. Suburban Furnace Installation Manual NT-20SEQ. The design of these furnaces has been certified for installation in recreational vehicles only. Furnace Cabinet. Update on what I wrote above. INSTALLER: AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO WATER HEATER. Your furnace was inspected before it left the factory. ! The. You should verify that the material used on the coach door, panel, or. Built with, Suburban 521137 RV Furnace Motor For NT-30 M/S/SP, AP Products 013-626 4 x 8 Brown Floor Register, Atwood 37357 Furnace Motor For 8531-35-III, DC 8935-40, JCJ Enterprises M-800 Furnace Insect Screen For 2004 Atwood Hydroflame, AP Products 013-625 4 x 8 White Floor Register, Atwood 37698 Furnace Blower Motor For 8535-IV, 8531-35-III, DC 8935-40, Suburban 062164 Bottom Duct Gasket For NT Series Furnaces, Suburban 2450A 19,000 BTU NT-SQ Series Ducted Furnace. NOTE: Side and top clearances of furnace cabinet may be 0" for through the wall, The following minimum clearances from the warm air discharge grille to, combustible materials must be maintained: See Figure 10 for 0" clearance of, Note: Must provide an additional 12 sq. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Direct vent gas water heater for installation in recreational vehicles and mobile housing, ! 2. Installation Requirem Ents (DD, NT and P Model Furnaces), Installation Requirem Ents (SF, SH and SHD-2542 Model Furnaces), Installation Requirem Ent (SFV Model Furnaces), Furnace Specifications (DD, NT and P Model Furnaces), Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces), Sequence of Operation (Tim E Delay Relay Equipped Furnaces), Sequence of Operation (Fan Control Module Board (520820) Equipped Furnaces), Sequence of Operation (24 VAC Fan Control Module Board (520947), Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board), Service Hints/Diagnosis/Corrective Measures, Service Hints, Diagnosis and Corrective Measures, For Suburban 24-Volt AC Electronic Ignition Furnaces, SF, SH and SHD-2542 Electrode Gap Specifications & Positioning, NT and Park Model Electrode Gap Specifications & Positioning, Suburban SF-35 Installation Instructions Manual (24 pages), Suburban SF-35 User's Information Manual (12 pages), Suburban SF-35 Installation Instructions Manual (9 pages). maintained around furnace cabinet so that the unit will be accessible for servicing. Never operate, These furnaces must be installed and vented as described in this manual so that, the negative pressure created by the air circulating (return air) fan cannot affect, the combustion air intake or venting of any other appliance. Determine "X" dimension as shown in Figure 1. Availability: In Stock Product Code: 42-0628. The Suburban Thermostat is a single-stage heat only RV thermostat that works perfectly with your furnace. 1) Tighten the screws securely. Suburban Furnace NT20SEQ Tune-Up Kit. The thermostat is equipped with a replaceable 2 amp fuse located on the base of the thermostat. Suburban forced draft combustion furnaces used in recreational vehicles are designed for use with Propane gas. When an appliance is installed directly on carpeting, tile, or other combustible, material other than wood flooring, the appliance shall be installed on a metal. If you are not a qualified service technician or an approved Suburban Service Agency, please click here to locate your nearest service center. OWNER: RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE. Suburban Water Heater Operation Manual - rvupgradestore.com 2. Operating Instructions. pressure for purposes of input adjustment: INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. Manuals; Brands; Suburban Manuals; Furnace; NT-20SEQ; . Any applicable local codes and regulations. View and Download Suburban SW6DEL installation and operation manual online. Left Side. White Rodgers 1C26 Thermostat User Manual, Emerson 1C26-101 Economy Mechanical Thermostat Owner's Manual, White Rodgers M30 M30 Heat Only Non-Programmable Thermostat Instructions / Assembly, White Rodgers M100 M100 Heat/Cool Mechanical Non-Programmable Thermostat Use and Care Manual, Emerson Low Voltage Mechanical Thermostat Owner's Manual, White Rodgers M150 Heat/Cool Mechanical Non-Programmable Thermostat Instructions / Assembly, Lenoxx Electronics G60DFV(X) Furnace User Manual, White Rodgers 1E56N-444 Installation and Operation Instructions, White Rodgers 1E30N-910 Thermostat User Manual, White Rodgers 1E50N-303 Thermostat User Manual, White Rodgers 1C21 Thermostat User Manual, Honeywell CT87J round Installation Instructions Manual, White Rodgers 1E30(W) Thermostat User Manual, Atwood AFS Series, AFSAD12, AFSD12, AFSD16, AFSD20 Training Manual, Honda Power Equipment GXI 60 Lawn Mower User Manual. for your safety what to do if you smell gas do not try to light any appliance. 148-08 Electrical, 3. Amazon.com: Suburban Rv Thermostat 1-16 of 52 results for "suburban rv thermostat" RESULTS Amazon's Choice Suburban 161154 Wall Thermostat - Heat Only - White 1,756 $2041$39.90 FREE delivery Fri, Feb 17 on $25 of items shipped by Amazon Or fastest delivery Thu, Feb 16 More Buying Choices $19.36 (18 new offers) Suburban 161154 Wall Thermostat 152 1A Auto is not responsible or liable for any loss damage (including, but not limited to, actual, consequential, or punitive), liability, claim, or any other injury or cause related to or resulting from any information posted in this video. manual . *Not Shown* Duct Cover. CSA Standard CAN/CSA Z240.6.2-08/C22.2 No. Do not install the. 4. Also for: Sw12del, Sw10del, Sw16del. D. Mount Thermostat Base: Gently push excess wire back into the wall opening and plug hole with a fire-resistant material, such as fiberglass insulation to prevent drafts from affecting thermostat operation. DO NOT STORE OR USE GASOLINE OR OTHER COMBUSTIBLE MATERIALS OR, LIQUIDS NEAR OR ADJACENT TO THIS HEATER OR ANY OTHER APPLIANCE. 4. AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. These thermostats are listed in chronological order from the oldest to the newest. Item# 1 Thermostat, Black. ! MFG P/N: 520788 MFG: Suburban Mfg UPC #: 765053276894 Quantity in Stock :22. Suburban Water Heater Master Service and Training Manual Suburban Water Heater Model SW6DE Tune-Up Kits Please Note: This kit is only applicable to the SW6DE model after serial number 953401118 Tune-Up Kit #1 120VAC Element / Switches Item#28 120VAC Element W/ Gasket (replaces p# 520789) Item#33 120VAC Element Switch (replaces p# 232362) Operating Humidity Range: 0 90% non-condensing. Suburban NT-20SEQ User's Information Manual (8 pages) The Suburban Thermostat is a single stage heat only RV thermostat that works perfectly with your furnace. Adhere to the following minimum clearances from the. Cut or frame an opening in the coach cabinetry 10, 5. The base, which is removed by loosening all captive screws. cover will not discolor or warp from the exhaust temperature whenever any door, CAUTION: Due to the differences in vinyl siding, this appliance should not, be installed on vinyl siding without first consulting with the manufacturer, of the siding or cutting the siding away from the area around the appliance, CAUTION: In any installation in which the vent of this appliance can be, covered due to the construction of the RV or some special feature of the, RV such as slide out, pop-up, etc. It is imperative that, the products of combustion be properly vented to the atmosphere and that all, combustion air supplied to burner be drawn from the outside atmosphere. Gas supply. in. We have 5 Suburban SF-35 manuals available for free PDF download: Service Manual, Installation Instructions Manual, User's Information Manual . Keep with unit at all times. furnace cabinet to combustible construction. The installation of the furnace shall be in accordance with any applicable local. REFER TO THIS MANUAL. No agent, representative or employee of Suburban or, other person has the authority to change, modify or waive any provision of the instructions, CAUTION: If possible, do not install the furnace to where the vent can be, covered or obstructed when any door on the trailer is opened. Replaces standard heat only systems, millivolt heat only systems, floor or wall furnaces, gas or oil heat, and hydronic (hot water) zone heat. Connecting Thermostat. In this video, 1A Auto shows how to remove, install, or replace a leaking or malfunctioning thermostat. In the absence. . 6. 1. Select a location for installation out of the way of wires, pipes, etc. 2. isolated from the room air. (See Fig. Failure to comply with the installation, instructions will void any responsibility of Airxcel, Inc., Suburban Division. The thermostat wiring is factory installed by the OEM (Original Equipment Manufacturer). Operating Humidity Range: 0 90% non-condensing. always insure that the appliance cannot, be operated by setting the thermostat to the positive "OFF" position and, shutting off all electrical and gas supply to the appliance. Item# 1 Thermostat, White. INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. o natural gas unless the conversion is approved, Volt ohm meter capable of testing above 15 amps, Do not sell or share my personal information. furnace with the vent facing toward the forward end of the coach. Z*H/gM1EAzb3Hjok%#4QT!9JAs{AL^gUk"V[eNC$Qmufu;0x` Any damages should be reported to the transportation company immediately and the appropriate. Installing Thermostat. Standard for Recreational Vehicles NFPA 1192. edition of the National Electrical Code NFPA 70. 6. This item Suburban 161154 Wall Thermostat - Heat Only - White Dometic 3316250.012 RV Thermostat (T-Stat,Ct Std-Blk-Boxed) Flame King (KT12ACR6a) 2-Stage Auto Changeover LP Propane Gas Regulator With Two 12 Inch Pigtails For RVs, Vans, Trailers 2023 Suburban, an Airxcel Brand - All Rights Reserved|676 Broadway Street, Dayton, Tennessee 37321| Phone: (423) 775-2131. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. Standard CAN/CSA Z240.4.2-08 Installation Requirements for Propane. REFER TO, THIS MANUAL. Standard CAN/CSA Z240.0.2-08 Recreational Vehicles. Temperature Range: 50F to 90F (10C to 32C). IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. furnace with the vent facing toward the forward end of the coach. THIS, APPLIANCE SHALL NOT BE INSTALLED IN ANY LOCATION WHERE FLAMMABLE. ! In Canada, the furnace must be installed in accordance with: 1. All Rights Reserved. * Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project. Making Electrical Connections 12 Volts D.C. Making Electrical Connections 120 Volts A.C. Parts Illustration and Replacement Parts List, Installation Using Flush Mount Frame & Door, Water Weeping or Dripping from Pressure Relief Valve, Water Heater Suburban SW10P Service Training Manual, Water Heater Suburban SWGDEL Installation And Operation Manual, Water Heater Suburban SW4DEL Installation And Operation Manual, Water Heater Suburban SW6D Installation And Operation Manual, Water Heater Suburban SW6P Installation And Operation Manual, Water Heater Suburban SW4P Installation And Operation Manual, Water Heater Suburban SW10D Installation And Operation Manual, Water Heater Suburban SW10DM Installation And Operation Manual, Water Heater Suburban SW12D Installation And Operation Manual, Water Heater Suburban SW3P Service Manual. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. Our current Document Library is in the process of being updated and documents will be housed on each specific products page. Suburban 161210 Wall Thermostat - Black Brand: SUBURBAN MFG 160 ratings -10% $2319 Was: $25.65 About this item Suburban part number: 161210 Suburban's goal is to manufacture the most durable and efficient products available See more product details Frequently bought together + + Total price: This item: Suburban 161210 Wall Thermostat - Black In the USA, the installation must conform with local building codes. 4. 12 V Heating: 0.15 to 1.2 Amps. Anticipator Rating: Heating - Adjustable from 0.15 to 1.2 Amps. Installing the suburban manual to a call and efficient dc motors are the market. MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. 1. Remove Old Thermostat: A standard heat/cool thermostat consists of two basic parts: a. The Suburban information I have found show the furnace expects the thermostat to have a set of NO contacts that go NC to call for heat. 10. Mechanical / By-Metal Thermostats Heating Anticipator 2.Electronic Thermostats 3.Electronic Digital Display Thermostats NOTE: ALL THREE OF THESE THERMOSTATS ARE COMPLETELY INTERCHANGEABLE. Installation of this appliance must be made in accordance with the written, instructions provided in this manual. Determine "Y" dimension as shown in Figure 1. Qty: DESCRIPTION The Suburban Thermostat Switch is an assembly part for Suburban water heaters. If this is not, possible, then the travel of the door must be restricted in order to provide, a 6" minimum clearance between the furnace vent and any door whenever, NOTE: The exhaust temperature of this furnace could discolor or warp some, materials. Slide the front of the furnace through the opening and extend it beyond the. Temperature Range: 50F to 90F (10C to 32C). If any parts are, found to be damaged do not install the furnace. Replaces standard heat only systems, millivolt heat only systems, floor or wall furnaces, gas or oil heat, and hydronic (hot water) zone heat. 2. Locate the furnace near lengthwise center of the coach. 6. The video is applicable to the 09 Chevrolet Suburban List of tools used: 15mm Wrench http://1aau.to/oie/1AXAA00010 10mm Socket http://1aau.to/oB2/1AXAA00017 8mm Socket http://1aau.to/oB2/1AXAA00017 Ratchet http://1aau.to/oQi/1AXAA00016 Socket Extensions http://1aau.to/oG2/1AXAA00015 Torque Wrench http://1aau.to/ono/1AXAA00044For More Info visit us at http://1aau.to/h/atR/ DISCLAIMER:While 1A Auto strives to make the information provided in this video as accurate as possible, it makes no claims, promises, or guarantees about the accuracy, completeness or applicability of the content. of return air when side clearance, 3. Temperature Range: 50F to 90F (10C to 32C). One of the two wires will be +12 volts (internally in the furnace) and the other is the command for heat. Locate the furnace near lengthwise center of the coach. Please Note: Suburban Gas Appliances are to be installed and/or serviced by a qualified service technician. It is the sole responsibility of the viewer to assume this risk.